Заказной номер | Описание |
6SL3211-0AB12-5UB1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.25KW; VT: 0.25KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT |
6SL3211-0AB13-7BA1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE |
6SL3211-0AB13-7BB1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG |
6SL3211-0AB13-7UA1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE |
6SL3211-0AB13-7UB1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT |
6SL3211-0AB15-5BA1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE |
6SL3211-0AB15-5BB1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG |
6SL3211-0AB15-5UA1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE |
6SL3211-0AB15-5UB1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT |
6SL3211-0AB17-5BA1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE |
6SL3211-0AB17-5BB1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT ANALOG |
6SL3211-0AB17-5UA1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE |
6SL3211-0AB17-5UB1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT ANALOG INPUT |
6SL3211-0AB21-1AA1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. A FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1.1KW; VT: 1.1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE |
6SL3211-0AB21-1AB1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. A FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 1.1KW; VT: 1.1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG I |
6SL3211-0AB21-1UA1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1.1KW; VT: 1.1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE |
6SL3211-0AB21-1UB1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 1.1KW; VT: 1.1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT |
6SL3211-0AB21-5AA1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. A FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1.5KW; VT: 1.5KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE |
6SL3211-0AB21-5AB1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. A FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 1.5KW; VT: 1.5KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT ANALOG I |
6SL3211-0AB21-5UA1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1.5KW; VT: 1.5KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE |