СИМЕНС 2008: Продукты каталога LV35: Низковольтовая коммутационная техника: автоматические выключатели 3VT
Заказной номер | Описание |
3VT8440-1BA03-...2 | CIRCUIT-BREAKER VT400 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 3- ПОЛЮСА, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 280..400A, OVERLOAD PROT. II = 4000A, SHORT-CIRCUIT PROT. |
3VT8440-1BA04-...2 | CIRCUIT-BREAKER VT400 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 4- ПОЛЮСА, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 280..400A, OVERLOAD PROT. II = 4000A, SHORT-CIRCUIT PROT. |
3VT8440-1CA03-...2 | CIRCUIT-BREAKER VT400 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 3- ПОЛЮСА, MOTOR PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 400A, OVERLOAD PROT. II = 4800A, SHORT-CIRCUIT PROT. |
3VT8440-1DA03-...2 | CIRCUIT-BREAKER VT400 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 3- ПОЛЮСА, MOTOR PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 280..400A, OVERLOAD PROT. II = 4800A, SHORT-CIRCUIT PROT. |
3VT8440-1EA03-...2 | CIRCUIT-BREAKER VT400 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 3- ПОЛЮСА,SYSTEM/MOTOR PROTECTION ELECTRONIC TRIP UNIT, IN=400A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. |
3VT8440-1EA04-...2 | CIRCUIT-BREAKER VT400 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 4- ПОЛЮСА,SYSTEM/MOTOR PROTECTION ELECTRONIC TRIP UNIT, IN=400A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. |
3VT8440-2AA03-...2 | CIRCUIT-BREAKER VT400 HIGH SWITCHING CAPACITY H ICU = 50 KA, 415/440 VAC 3- ПОЛЮСА, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 400A, OVERLOAD PROT. II = 4000A, SHORT-CIRCUIT PROT. |
3VT8440-2AA04-...2 | CIRCUIT-BREAKER VT400 HIGH SWITCHING CAPACITY H ICU = 50 KA, 415/440 VAC 4- ПОЛЮСА, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 400A, OVERLOAD PROT. II = 4000A, SHORT-CIRCUIT PROT. |
3VT8440-2BA03-...2 | CIRCUIT-BREAKER VT400 HIGH SWITCHING CAPACITY H ICU = 50 KA, 415/440 VAC 3- ПОЛЮСА, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 280..400A, OVERLOAD PROT. II = 4000A, SHORT-CIRCUIT PROT. |
3VT8440-2BA04-...2 | CIRCUIT-BREAKER VT400 HIGH SWITCHING CAPACITY H ICU = 50 KA, 415/440 VAC 4- ПОЛЮСА, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 280..400A, OVERLOAD PROT. II = 4000A, SHORT-CIRCUIT PROT. |
3VT8440-2CA03-...2 | CIRCUIT-BREAKER VT400 HIGH SWITCHING CAPACITY H ICU = 50 KA, 415/440 VAC 3- ПОЛЮСА, MOTOR PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 400A, OVERLOAD PROT. II = 4800A, SHORT-CIRCUIT PROT. |
3VT8440-2DA03-...2 | CIRCUIT-BREAKER VT400 HIGH SWITCHING CAPACITY H ICU = 50 KA, 415/440 VAC 3- ПОЛЮСА, MOTOR PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 280..400A, OVERLOAD PROT. II = 4800A, SHORT-CIRCUIT PROT. |
3VT8440-2EA03-...2 | CIRCUIT-BREAKER VT400 HIGH SWITCHING CAPACITY H ICU = 50 KA, 415/440 VAC 3- ПОЛЮСА,SYSTEM/MOTOR PROTECTION ELECTRONIC TRIP UNIT, IN=400A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. |
3VT8440-2EA04-...2 | CIRCUIT-BREAKER VT400 HIGH SWITCHING CAPACITY H ICU = 50 KA, 415/440 VAC 4- ПОЛЮСА,SYSTEM/MOTOR PROTECTION ELECTRONIC TRIP UNIT, IN=400A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. |
3VT8540-1AA03-...2 | CIRCUIT-BREAKER VT630 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 3- ПОЛЮСА, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 400A, OVERLOAD PROT. II = 4000A, SHORT-CIRCUIT PROT. |
3VT8540-1AA04-...2 | CIRCUIT-BREAKER VT630 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 4- ПОЛЮСА, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 400A, OVERLOAD PROT. II = 4000A, SHORT-CIRCUIT PROT. |
3VT8540-1EA03-...2 | CIRCUIT-BREAKER VT630 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 3- ПОЛЮСА, SYSTEM PROTECTION ELECTRONIC TRIP UNIT, IN=400A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. |
3VT8540-1EA04-...2 | CIRCUIT-BREAKER VT630 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 4- ПОЛЮСА, SYSTEM PROTECTION ELECTRONIC TRIP UNIT, IN=400A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. |
3VT8540-1FA03-...2 | CIRCUIT-BREAKER VT630 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 3- ПОЛЮСА, SYSTEM PROTECTION ELECTRONIC TRIP UNIT, IN=400A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 10 X IN, SHORT-CIRCUIT PROT. |
3VT8540-1FA04-...2 | CIRCUIT-BREAKER VT630 STANDARD SWITCHING CAPACITY N ICU = 35 KA, 415/440 VAC 4- ПОЛЮСА, SYSTEM PROTECTION ELECTRONIC TRIP UNIT, IN=400A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 10 X IN, SHORT-CIRCUIT PROT. |
|