Планирование запасных частей - OXYMAT 6 |
Дальнейшая информация
Description
|
7MB2021
|
7MB2011
|
7MB2011 Ex
|
2 years (Stück)
|
5 years (Stück)
|
Order No.
|
Analyzer section
|
|
|
|
|
|
|
O-ring (stub)
|
x
|
x
|
x
|
2
|
4
|
C71121-Z100-A159
|
O-ring
|
x
|
|
|
1
|
2
|
C74121-Z100-A6
|
O-ring (measuring head)
|
x
|
x
|
x
|
2
|
4
|
C79121-Z100-A32
|
Spacer
|
x
|
x
|
x
|
-
|
1
|
C79451-A3277-B22
|
Sample cell, SS, type No. 1.4571, non-flow type compensation circuit
|
x
|
x
|
x
|
-
|
1
|
C79451-A3277-B535
|
Sample cell, tantalum, non-flow type compensation circuit
|
x
|
x
|
x
|
-
|
1
|
C79451-A3277-B536
|
Sample cell, SS, type No. 1.4571, flow type compensation circuit
|
x
|
x
|
x
|
-
|
1
|
C79451-A3277-B537
|
Sample cell, tantalum, flow type compensation circuit
|
x
|
x
|
x
|
-
|
1
|
C79451-A3277-B538
|
Measuring head, non-flow type compensation circuit
|
x
|
x
|
x
|
1
|
1
|
C79451-A3460-B525
|
Measuring head, flow type compensation circuit
|
x
|
x
|
x
|
1
|
1
|
C79451-A3460-B526
|
Magnetic connection plate
|
x
|
x
|
x
|
-
|
1
|
C79451-A3474-B606
|
Temperature sensor
|
x
|
x
|
x
|
-
|
1
|
C79451-A3480-B25
|
Heating inset
|
x
|
x
|
x
|
-
|
1
|
W75083-A1004-F120
|
Sample gas path
|
|
|
|
|
|
|
Pressure switch (sample gas)
|
x
|
|
|
1
|
2
|
C79302-Z1210-A2
|
Flowmeter (version with pump only)
|
x
|
|
|
1
|
2
|
C79402-Z560-T1
|
Restriction, SS type No. 1.4571, gas path hose
|
x
|
|
|
2
|
2
|
C79451-A3480-C10
|
Restriction, titanium, gas path pipe
|
x
|
x
|
x
|
2
|
2
|
C79451-A3480-C37
|
Reference gas path, 3000 hPa
|
x
|
x
|
x
|
1
|
1
|
C79451-A3480-D518
|
Capillary tube, 100 hPa, connection kit
|
x
|
x
|
x
|
1
|
1
|
C79451-A3480-D519
|
Restriction, SS type No. 1.4571, gas path pipe
|
x
|
x
|
x
|
1
|
1
|
C79451-A3250-C5
|
Electronic
|
|
|
|
|
|
|
Temperature controller - electronic, 230 V AC
|
|
x
|
x
|
-
|
1
|
A5E00118527
|
Temperature controller - electronic, 115V AC
|
|
x
|
x
|
-
|
1
|
A5E00118530
|
Fuse (unit fuse)
|
|
|
x
|
1
|
2
|
A5E00061501
|
Front panel with keyboard
|
x
|
|
|
1
|
1
|
C79165-A3042-B505
|
Temperature controller
|
x
|
x
|
x
|
-
|
1
|
C79451-A3474-B56
|
Base plate, without firmware
|
x
|
x
|
x
|
-
|
1
|
C79451-A3474-B601
|
Adapter board, LCD/keyboard
|
x
|
x
|
|
1
|
1
|
C79451-A3474-B605
|
LC display
|
x
|
x
|
|
1
|
1
|
W75025-B5001-B1
|
Connector filter
|
x
|
x
|
x
|
-
|
1
|
W75041-E5602-K2
|
Temperature fuse (heated version only)
|
|
x
|
|
-
|
1
|
W75054-T1001-A150
|
Fuse, T 0.63/250 V
|
x
|
x
|
x
|
2
|
4
|
W75054-L1010-T630
|
Fuse, 1 A, 110/220 V
|
x
|
x
|
x
|
2
|
4
|
W75054-L1011-T100
|
Fuse, 2.5 A, 250 V
|
|
x
|
x
|
2
|
3
|
W75054-L1011-T250
|
If the OXYMAT 6 was delivered with specially cleaned gas path for high oxygen content (so-called „Cleaned for O2 service“), please absolutely specify it for a spare part order. This is the only way to guarantee that the gas path furthermore corresponds to the special requirements for this variant.
|